Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
Front Cardiovasc Med ; 10: 1285391, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38107261

RESUMO

Background: Severe left-sided cardiac obstructions are associated with high morbidity and mortality if not detected in time. The correct prenatal diagnosis of coarctation of the aorta (CoA) is difficult. Fetal cardiac magnetic resonance imaging (CMR) may improve the prenatal diagnosis of complex congenital heart defects. Flow measurements in the ascending aorta could aid in predicting postnatal CoA, but its accurate visualization is challenging. Objectives: To compare the flow in the descending aorta (DAo) and umbilical vein (UV) in fetuses with suspected left-sided cardiac obstructions with and without the need for postnatal intervention and healthy controls by fetal phase-contrast CMR flow. A second objective was to determine if adding fetal CMR to echocardiography (echo) improves the fetal CoA diagnosis. Methods: Prospective fetal CMR phase-contrast flow in the DAo and UV and echo studies were conducted between 2017 and 2022. Results: A total of 46 fetuses with suspected left-sided cardiac obstructions [11 hypoplastic left heart syndrome (HLHS), five critical aortic stenosis (cAS), and 30 CoA] and five controls were included. Neonatal interventions for left-sided cardiac obstructions (n = 23) or comfort care (n = 1 with HLHS) were pursued in all 16 fetuses with suspected HLHS or cAS and in eight (27%) fetuses with true CoA. DAo or UV flow was not different in fetuses with and without need of intervention. However, DAo and UV flows were lower in fetuses with either retrograde isthmic systolic flow [DAo flow 253 (72) vs. 261 (97) ml/kg/min, p = 0.035; UV flow 113 (75) vs. 161 (81) ml/kg/min, p = 0.04] or with suspected CoA and restrictive atrial septum [DAo flow 200 (71) vs. 268 (94) ml/kg/min, p = 0.04; UV flow 89 vs. 159 (76) ml/kg/min, p = 0.04] as well as in those without these changes. Adding fetal CMR to fetal echo predictors for postnatal CoA did not improve the diagnosis of CoA. Conclusion: Fetal CMR-derived DAo and UV flow measurements do not improve the prenatal diagnosis of left-sided cardiac obstructions, but they could be important in identifying fetuses with a more severe decrease in blood flow across the left side of the heart. The physiological explanation may be a markedly decreased left ventricular cardiac output with subsequent retrograde systolic isthmic flow and decreased total DAo flow.

2.
Sci Rep ; 13(1): 18206, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37875552

RESUMO

In Fontan patients, a lung deprived of hepatic blood may develop pulmonary arterio-venous malformations (PAVMs) resulting in shunting, reduced pulmonary vascular resistance (PVR) and decreased oxygenation. To provide guidance for corrective invasive interventions, we aimed to non-invasively determine how the hepatic to pulmonary blood flow balance correlates with pulmonary flow, PVR, and with oxygen saturation. Magnetic resonance imaging (MRI) data from eighteen Fontan patients (eight females, age 3-14 years) was used to construct patient-specific computational fluid dynamics (CFD) models to calculate the hepatic to pulmonary blood flow. This was correlated with pulmonary vein flow, simulated PVR and oxygen saturation. Clinical applicability of the findings was demonstrated with an interventional patient case. The hepatic to pulmonary blood flow balance correlated with right/left pulmonary vein flow (R2 = 0.50), left/right simulated PVR (R2 = 0.47), and oxygen saturation at rest (R2 = 0.56). In the interventional patient, CFD predictions agreed with post-interventional MRI measurements and with regressions in the cohort. The balance of hepatic blood to the lungs has a continuous effect on PVR and oxygen saturation, even without PAVM diagnosis. MRI combined with CFD may help in planning of surgical and interventional designs affecting the hepatic to pulmonary blood flow balance in Fontan patients.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Feminino , Humanos , Pré-Escolar , Criança , Adolescente , Artéria Pulmonar , Hidrodinâmica , Pulmão , Circulação Pulmonar
3.
Pediatr Cardiol ; 2023 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-37596421

RESUMO

Left ventricular shape alterations predict cardiovascular outcomes and have been observed in children born preterm and after fetal growth restriction (FGR). The aim was to investigate whether left ventricular shape is altered in adolescents born very preterm and if FGR has an additive effect. Adolescents born very preterm due to verified early-onset FGR and two control groups with birthweight appropriate for gestational age (AGA), born at similar gestational age and at term, respectively, underwent cardiac MRI. Principal component analysis was applied to find the modes of variation best explaining shape variability for end-diastole, end-systole, and for the combination of both, the latter indicative of function. Seventy adolescents were included (13-16 years; 49% males). Sphericity was increased for preterm FGR versus term AGA for end-diastole (36[0-60] vs - 42[- 82-8]; p = 0.01) and the combined analysis (27[- 23-94] vs - 51[- 119-11]; p = 0.01), as well as for preterm AGA versus term AGA for end-diastole (30[- 56-115] vs - 42[- 82-8]; p = 0.04), for end-systole (57[- 29-89] vs - 30[- 79-34]; p = 0.03), and the combined analysis (44[- 50-145] vs - 51[- 119-11]; p = 0.02). No group differences were observed for left ventricular mass or ejection fraction (all p ≥ 0.33). Sphericity was increased after very preterm birth and exacerbated by early-onset FGR, indicating an additive effect to that of very preterm birth on left ventricular remodeling. Increased sphericity may be a prognostic biomarker of future cardiovascular disease in this cohort that as of yet shows no signs of cardiac dysfunction using standard clinical measurements.

4.
Magn Reson Med ; 90(6): 2472-2485, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37582228

RESUMO

PURPOSE: To ultimately make accurate and precise fetal noninvasive oxygen saturation (sO2 ) measurements by T2 -prepared bSSFP more widely available by systematically assessing error sources in order to potentially reduce perinatal mortality in cardiovascular malformations and fetal growth restriction. METHODS: T2 -prepared bSSFP data were acquired in phantoms; in flowing blood in adults in the superior sagittal sinus, ascending and descending aorta, and main pulmonary artery; and in the fetal descending aorta and umbilical vein. T2 was assessed in relation to T2 two- or three-parameter curve-fitting techniques, SSFP readout, refocusing time delay (τ), constant and pulsatile blood flow, and impact of T1 recovery. Further, fetal T2 and sO2 variability were quantified in the descending aorta and umbilical vein in healthy fetuses and fetuses with cardiovascular malformation (gestational weeks 32-38). RESULTS: In phantoms, three-parameter fitting was accurate irrespective of phase FOV (<4 ms; i.e., <2%), and T2 was overestimated (up to 23 ms/10%; p = 0.001) beyond ±30 Hz off-resonance. In the adult aorta, T2 was underestimated during higher blood flow velocities and pulsatility for τ = 16 ms (-41 ms/-17%; p = 0.008). In fetuses, two-parameter fitting overestimated T2 compared with three-parameter fitting (+33 ms/+18%; p = 0.03). T2 variability was 18 ms/15% in the fetal descending aorta and 28 ms/14% in the umbilical vein. The resulting estimated sO2 variability was ∼10% (15% of sO2 value) in the fetal descending aorta. CONCLUSIONS: Errors due to T2 -fitting techniques, off-resonance, flow velocity, and insufficient T1 recovery between image acquisitions could be mitigated by using three-parameter fitting with included saturation-prepared images approximating infinite T2 -preparation time, adequate shimming covering the fetus and placenta, and by modifying acquisition parameters. Variability in fetal blood T2 and sO2 , however, indicate that it is currently not feasible to use these methods for prediction of disease.


Assuntos
Sangue Fetal , Saturação de Oxigênio , Gravidez , Feminino , Adulto , Humanos , Feto/diagnóstico por imagem , Hemodinâmica/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Oxigênio
6.
Int J Cardiovasc Imaging ; 39(2): 401-409, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36115891

RESUMO

Experimental data on pulmonary regurgitation has linked right ventricular longitudinal function to left ventricular filling pressure in animals with induced and treated pulmonary regurgitation but this relationship has not been investigated in patients with repaired Tetralogy of Fallot (rToF). The aim of this study was to determine if right ventricular longitudinal function assessed using cardiovascular magnetic resonance (CMR) is associated with left ventricular filling pressure in patients with rToF. A second objective of this study was to determine if direction of septal movement is related to right ventricular pressure load in rToF. Eighteen patients with rToF undergoing CMR and heart catheterization prior to pulmonary valve replacement were retrospectively included and catheter-based pressure measurements were compared with CMR-derived RV regional function. Left ventricular filling pressure was measured as precapillary wedge pressure (PCWP). Longitudinal contribution to RV stroke volume correlated with PCWP (r = 0.48; p = 0.046) but not with RV EF or pulmonary regurgitation. Neither RV longitudinal strain nor TAPSE showed correlation with PCWP. Longitudinal contribution to stroke volume was lower for the RV compared to the LV (49 vs 54%; p = 0.039). Direction of septal movement did not show a correlation with RV end-systolic pressure. Right ventricular longitudinal pumping is associated with left ventricular filling pressure in rToF-patients and this inter-ventricular coupling may explain LV underfilling in patients with pulmonary regurgitation and rToF and may be of value to determine right ventricular dysfunction. RV systolic pressure, however, cannot be assessed from the direction of septal movement, in these patients.


Assuntos
Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Disfunção Ventricular Direita , Humanos , Estudos Retrospectivos , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética , Função Ventricular Direita
7.
J Magn Reson Imaging ; 57(1): 71-82, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35726779

RESUMO

BACKGROUND: Neonates with critical congenital heart disease require early intervention. Four-dimensional (4D) flow may facilitate surgical planning and improve outcome, but accuracy and precision in neonates are unknown. PURPOSE: To 1) validate two-dimensional (2D) and 4D flow MRI in a phantom and investigate the effect of spatial and temporal resolution; 2) investigate accuracy and precision of 4D flow and internal consistency of 2D and 4D flow in neonates; and 3) compare scan time of 4D flow to multiple 2D flows. STUDY TYPE: Phantom and prospective patients. POPULATION: A total of 17 neonates with surgically corrected aortic coarctation (age 18 days [IQR 11-20]) and a three-dimensional printed neonatal aorta phantom. FIELD STRENGTH/SEQUENCE: 1.5T, 2D flow and 4D flow. ASSESSMENT: In the phantom, 2D and 4D flow volumes (ascending and descending aorta, and aortic arch vessels) with different resolutions were compared to high-resolution reference 2D flow. In neonates, 4D flow was compared to 2D flow volumes at each vessel. Internal consistency was computed as the flow volume in the ascending aorta minus the sum of flow volumes in the aortic arch vessels and descending aorta, divided by ascending aortic flow. STATISTICAL TESTS: Bland-Altman plots, Pearson correlation coefficient (r), and Student's t-tests. RESULTS: In the phantom, 2D flow differed by 0.01 ± 0.02 liter/min with 1.5 mm spatial resolution and -0.01 ± 0.02 liter/min with 0.8 mm resolution; 4D flow differed by -0.05 ± 0.02 liter/min with 2.4 mm spatial and 42 msec temporal resolution, -0.01 ± 0.02 liter/min with 1.5 mm, 42 msec resolution and -0.01 ± 0.02 liter/min with 1.5 mm, 21 msec resolution. In patients, 4D flow and 2D flow differed by -0.06 ± 0.08 liter/min. Internal consistency in patients was -11% ± 17% for 2D flow and 5% ± 13% for 4D flow. Scan time was 17.1 minutes [IQR 15.5-18.5] for 2D flow and 6.2 minutes [IQR 5.3-6.9] for 4D flow, P < 0.0001. DATA CONCLUSION: Neonatal 4D flow MRI is time efficient and can be acquired with good internal consistency without contrast agents or general anesthesia, thus potentially expanding 4D flow use to the youngest and smallest patients. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Recém-Nascido , Humanos , Adolescente , Imageamento Tridimensional/métodos , Velocidade do Fluxo Sanguíneo , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Anestesia Geral , Reprodutibilidade dos Testes
8.
Magn Reson Med ; 89(2): 594-604, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36156292

RESUMO

PURPOSE: To explore a fetal 3D cardiovascular cine acquisition using a radial image acquisition and compressed-sensing reconstruction and compare image quality and scan time with conventional multislice 2D imaging. METHODS: Volumetric fetal cardiac data were acquired in 26 volunteers using a radial 3D balanced SSFP pulse sequence. Cardiac gating was performed using a Doppler ultrasound device. Images were reconstructed using a parallel-imaging and compressed-sensing algorithm. Multiplanar reformatting to standard cardiac views was performed before image analysis. Clinical 2D images were used for comparison. Qualitative and quantitative image evaluation were performed by two experienced observers (scale: 1-4). Volumes, mass, and function were assessed. RESULTS: Average scan time for the 3D imaging was 6 min, including one localizer. A 2D imaging stack covering the entire heart including localizer sequences took at least 6.5 min, depending on planning complexity. The 3D acquisition was successful in 7 of 26 subjects (27%). Overall image contrast and perceived resolution were lower in the 3D images. Nonetheless, the 3D images had, on average, a moderate cardiac diagnostic quality (median [range]: 3 [1-4]). Standard clinical 2D acquisitions had a high cardiac diagnostic quality (median [range]: 4 [3, 4]). Cardiac measurements were not different between 2D and 3D images (all p > 0.16). CONCLUSION: The presented free-breathing whole-heart fetal 3D radial cine MRI acquisition and reconstruction method enables retrospective visualization of all cardiac views while keeping examination times short. This proof-of-concept work produced images with diagnostic quality, while at the same time reducing the planning complexity to a single localizer.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Interpretação de Imagem Assistida por Computador/métodos , Estudos Retrospectivos , Suspensão da Respiração , Imagem Cinética por Ressonância Magnética/métodos
9.
Pediatr Nephrol ; 38(6): 1855-1866, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36409369

RESUMO

BACKGROUND: Preterm birth and fetal growth restriction (FGR) are associated with structural and functional kidney changes, increasing long-term risk for chronic kidney disease and hypertension. However, recent studies in preterm children are conflicting, indicating structural changes but normal kidney function. This study therefore assessed kidney structure and function in a cohort of adolescents born very preterm with and without verified FGR. METHODS: Adolescents born very preterm with FGR and two groups with appropriate birthweight (AGA) were included; one matched for gestational week at birth and one born at term. Cortical and medullary kidney volumes and T1 and T2* mapping values were assessed by magnetic resonance imaging. Biochemical markers of kidney function and renin-angiotensin-aldosterone system (RAAS) activation were analyzed. RESULTS: Sixty-four adolescents were included (13-16 years; 48% girls). Very preterm birth with FGR showed smaller total (66 vs. 75 ml/m2; p = 0.01) and medullary volume (19 vs. 24 ml/m2; p < 0.0001) compared to term AGA. Corticomedullary volume ratio decreased from preterm FGR (2.4) to preterm AGA (2.2) to term AGA (1.9; p = 0.004). There were no differences in T1 or T2* values (all p ≥ 0.34) or in biochemical markers (all p ≥ 0.12) between groups. CONCLUSIONS: FGR with abnormal fetal blood flow followed by very preterm birth is associated with smaller total kidney and medullary kidney volumes, but not with markers of kidney dysfunction or RAAS activation in adolescence. Decreased total kidney and medullary volumes may still precede a long-term decrease in kidney function, and potentially be used as a prognostic marker. A higher resolution version of the Graphical abstract is available as Supplementary information.


Assuntos
Hipertensão , Nascimento Prematuro , Criança , Feminino , Recém-Nascido , Adolescente , Humanos , Masculino , Retardo do Crescimento Fetal/patologia , Peso ao Nascer , Rim/patologia , Idade Gestacional
10.
Pediatr Cardiol ; 44(6): 1311-1318, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36334112

RESUMO

Magnetic resonance imaging (MRI) provides images for estimating fetal volume and weight, but manual delineations are time consuming. The aims were to (1) validate an algorithm to automatically quantify fetal volume by MRI; (2) compare fetal weight by Hadlock's formulas to that of MRI; and (3) quantify fetal blood flow and index flow to fetal weight by MRI. Forty-two fetuses at 36 (29-39) weeks gestation underwent MRI. A neural network was trained to segment the fetus, with 20 datasets for training and validation, and 22 for testing. Hadlock's formulas 1-4 with biometric parameters from MRI were compared with weight by MRI. Blood flow was measured using phase-contrast MRI and indexed to fetal weight. Bland-Altman analysis assessed the agreement between automatic and manual fetal segmentation and the agreement between Hadlock's formulas and fetal segmentation for fetal weight. Bias and 95% limits of agreement were for automatic versus manual measurements 4.5 ± 351 ml (0.01% ± 11%), and for Hadlock 1-4 vs MRI 108 ± 435 g (3% ± 14%), 211 ± 468 g (7% ± 15%), 106 ± 425 g (4% ± 14%), and 179 ± 472 g (6% ± 15%), respectively. Umbilical venous flow was 406 (range 151-650) ml/min (indexed 162 (range 52-220) ml/min/kg), and descending aortic flow was 763 (range 481-1160) ml/min (indexed 276 (range 189-386) ml/min/kg). The automatic method showed good agreement with manual measurements and saves considerable analysis time. Hadlock 1-4 generally agree with MRI. This study also illustrates the confounding effects of fetal weight on absolute blood flow, and emphasizes the benefit of indexed measurements for physiological assessment.


Assuntos
Aprendizado Profundo , Peso Fetal , Humanos , Imageamento por Ressonância Magnética , Feto/diagnóstico por imagem , Idade Gestacional
11.
Pediatr Res ; 93(7): 2019-2027, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36344695

RESUMO

BACKGROUND: Although preterm birth predisposes for cardiovascular disease, recent studies in children indicate normal blood pressure and arterial stiffness. This prospective cohort study therefore assessed blood pressure and arterial stiffness in adolescents born very preterm due to verified fetal growth restriction (FGR). METHODS: Adolescents (14 (13-17) years; 52% girls) born very preterm with FGR (preterm FGR; n = 24) and two control groups born with appropriate birth weight (AGA), one in similar gestation (preterm AGA; n = 27) and one at term (term AGA; n = 28) were included. 24-hour ambulatory blood pressure and aortic pulse wave velocity (PWV) and distensibility by magnetic resonance imaging were acquired. RESULTS: There were no group differences in prevalence of hypertension or in arterial stiffness (all p ≥ 0.1). In boys, diastolic and mean arterial blood pressures increased from term AGA to preterm AGA to preterm FGR with higher daytime and 24-hour mean arterial blood pressures in the preterm FGR as compared to the term AGA group. In girls, no group differences were observed (all p ≥ 0.1). CONCLUSIONS: Very preterm birth due to FGR is associated with higher, yet normal blood pressure in adolescent boys, suggesting an existing but limited impact of very preterm birth on cardiovascular risk in adolescence, enhanced by male sex and FGR. IMPACT: Very preterm birth due to fetal growth restriction was associated with higher, yet normal blood pressure in adolescent boys. In adolescence, very preterm birth due to fetal growth restriction was not associated with increased thoracic aortic stiffness. In adolescence, very preterm birth in itself showed an existing but limited effect on blood pressure and thoracic aortic stiffness. Male sex and fetal growth restriction enhanced the effect of preterm birth on blood pressure in adolescence. Male sex and fetal growth restriction should be considered as additional risk factors to that of preterm birth in cardiovascular risk stratification.


Assuntos
Hipertensão , Nascimento Prematuro , Criança , Feminino , Humanos , Recém-Nascido , Masculino , Adolescente , Pressão Sanguínea/fisiologia , Estudos Prospectivos , Monitorização Ambulatorial da Pressão Arterial , Análise de Onda de Pulso , Retardo do Crescimento Fetal , Desenvolvimento Fetal , Idade Gestacional
13.
Pediatr Cardiol ; 43(7): 1631-1644, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35396945

RESUMO

Pulse wave velocity (PWV) by cardiovascular magnetic resonance (CMR) lacks standardization. The aim of this study was to investigate methodological aspects of PWV measurements by CMR in neonates and adolescents. A computer phantom was created to validate the temporal resolution required for accurate PWV. Fifteen neonates and 71 adolescents underwent CMR with reference standard 3D angiography and phase-contrast flow acquisitions, and in a subset coronal overview images. Velocity and flow curves, transit time methods (time-to-foot (TTF), maximum upslope, and time-to-peak (TTP)), and baseline correction methods (no correction, automatic and manual) were investigated. In neonates, required timeframes per cardiac cycle for accurate PWV was 42 for the aortic arch and 41 for the thoracic aorta. In adolescents, corresponding values were 39 and 32. Aortic length differences by overview images and 3D angiography in adolescents were - 16-18 mm (aortic arch) and - 25-30 mm (thoracic aorta). Agreement in PWV between automatic and manual baseline correction was - 0.2 ± 0.3 m/s in neonates and 0.0 ± 0.1 m/s in adolescents. Velocity and flow-derived PWV measurements did not differ in either group (all p > 0.08). In neonates, transit time methods did not differ (all p > 0.19) but in adolescents PWV was higher for TTF (3.8 ± 0.5 m/s) and maximum upslope (3.7 ± 0.6 m/s) compared to TTP (2.7 ± 1.0 m/s; p < 0.0001). This study is a step toward standardization of PWV in neonates and adolescents using CMR. It provides required temporal resolution for phase-contrast flow acquisitions for typical heartrates in neonates and adolescents, and supports 3D angiography and time-to-foot with automatic baseline correction for accurate PWV measurements.


Assuntos
Análise de Onda de Pulso , Rigidez Vascular , Adolescente , Aorta/patologia , Velocidade do Fluxo Sanguíneo , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Análise de Onda de Pulso/métodos , Reprodutibilidade dos Testes
16.
Acta Radiol Open ; 11(1): 20584601211072281, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35096415

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) biomarkers can diagnose and prognosticate kidney disease. Renal volume validation studies are however scarce, and measurements are limited by use of contrast agent or advanced post-processing. PURPOSE: To validate a widely available non-contrast-enhanced MRI method for quantification of renal cortical and medullary volumes in pigs; investigate observer variability of cortical and medullary volumes in humans; and present reference values for renal cortical and medullary volumes in adolescents. MATERIALS AND METHODS: Cortical and medullary volumes were quantified from transaxial in-vivo water-excited MR images in six pigs and 15 healthy adolescents (13-16years). Pig kidneys were excised, and renal cortex and medulla were separately quantified by the water displacement method. Both limits of agreement by the Bland-Altman method and reference ranges are presented as 2.5-97.5 percentiles. RESULTS: Agreement between MRI and ex-vivo quantification were -7 mL (-10-0 mL) for total parenchyma, -4 mL (-9-3 mL) for cortex, and -2 mL (-7-2 mL) for medulla. Intraobserver variability for pig and human kidneys were <5% for total parenchyma, cortex, and medulla. Interobserver variability for both pig and human kidneys were ≤4% for total parenchyma and cortex, and 6% and 12% for medulla. Reference ranges indexed for body surface area and sex were 54-103 mL/m2 (boys) and 56-103 mL/m2 (girls) for total parenchyma, 39-62 mL/m2 and 36-68 mL/m2 for cortex, and 16-45 mL/m2 and 17-42 mL/m2 for medulla. CONCLUSION: The proposed widely available non-contrast-enhanced MRI method can quantify cortical and medullary renal volumes and can be directly implemented clinically.

17.
J Magn Reson Imaging ; 56(1): 223-231, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34652860

RESUMO

BACKGROUND: Fetal cardiac magnetic resonance imaging (MRI) improves the diagnosis of congenital heart defects, but is sensitive to fetal motion due to long image acquisition time. This may be overcome with faster image acquisition with low resolution, followed by image enhancement to provide clinically useful images. PURPOSE: To combine phase-encoding undersampling with super-resolution neural networks to achieve high-resolution fetal cine cardiac MR images with short acquisition time. STUDY TYPE: Prospective. SUBJECTS: Twenty-eight fetuses (gestational week 36 [interquartile range 33-38 weeks]). FIELD STRENGTH/SEQUENCE: 1.5 T, balanced steady-state free precession (bSSFP) cine sequence. ASSESSMENT: Images were acquired using fully sampled Doppler ultrasound-gated clinical bSSFP cine as reference, with equivalent cine sequences with decreased phase-encoding resolution (25%, 33%, and 50% of clinical standard). Two super-resolution methods based on convolutional neural networks were proposed and evaluated (phasrGAN and phasrresnet). Data were partitioned into training (36 cine slices), validation (3 cine slices), and test sets (67 cine slices) without overlap. Conventional reconstruction methods using bicubic interpolation and k-space zeropadding were used for comparison. Three blinded observers scored image quality between 1 and 10. STATISTICAL TESTS: Image scores are reported as median [interquartile range] and were compared using Mann-Whitney's nonparametric test with P < 0.05 showing statistically significant differences. RESULTS: Both proposed methods showed no significant difference in image quality compared to clinical images (8 [7-8.5]) down to 33% (phasrGAN 8 [6.5-8]; phasrresnet 8 [7-8], all P ≥ 0.19) phase-encoding resolution, i.e., up to three times faster image acquisition, whereas bicubic interpolation and k-space zeropadding showed significantly lower quality for 33% phase-encoding resolution (both 7 [6-8]). DATA CONCLUSION: Super-resolution enhancement can be used for fetal cine cardiac MRI to reduce image acquisition time while maintaining image quality. This may lead to an improved success rate for fetal cine MR imaging, as the impact of fetal motion is lessened by shortened acquisitions. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Feminino , Feto/diagnóstico por imagem , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes
18.
BMJ Open ; 11(10): e053179, 2021 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-34635530

RESUMO

OBJECTIVES: Previous studies have investigated the association between socioeconomic characteristics and fractures among children, producing different results. In a population-based study, we previously found an increased risk of fractures among children living in an urban municipality compared with rural municipalities. This study aimed to evaluate the importance of socioeconomic variables for the incidence of fractures among 0-17 year olds. SETTING, DESIGN AND OUTCOME MEASURE: We present a longitudinal, observational study of a population 0-17 years of age. Data from an injury database were linked with additional socioeconomic data for the population at risk. These were 55 758 individuals residing within the primary catchment area of a regional hospital in northern Sweden. Using the number of fractures as the outcome, we fitted a generalised linear mixed model for a Poisson response with socioeconomic variables at the family level as independent variables while controlling for age, sex and place of residence. RESULTS: We found a significant association between higher levels of family income and the risk of fracture, rate ratio 1.40 (1.28-1.52) p<0.001 when comparing the highest income quintile to the lowest as well as the number of siblings and the risk of fracture. Children with one or two siblings had a rate ratio of 1.28 (1.19-1.38) p<0.001 when compared with children with no siblings. Parents' educational level and having a single parent showed no significant association with fractures. The previously observed association between municipalities and fracture risk was less pronounced when taking family-level socioeconomic variables into account. CONCLUSION: Our results indicate that children from families with higher income and with siblings are at greater risk of sustaining fractures.


Assuntos
Renda , Adolescente , Criança , Humanos , Incidência , Fatores de Risco , Fatores Socioeconômicos , Suécia/epidemiologia
19.
JAMA Netw Open ; 4(3): e213538, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33779747

RESUMO

Importance: Prenatal diagnosis of complex congenital heart defects reduces mortality and morbidity in affected infants. However, fetal echocardiography can be limited by poor acoustic windows, and there is a need for improved diagnostic methods. Objective: To assess the clinical utility of fetal cardiovascular magnetic resonance imaging in cases in which fetal echocardiography could not visualize all relevant anatomy. Design, Setting, and Participants: This cohort study was conducted between January 20, 2017, and June 29, 2020, at Skåne University Hospital (Lund, Sweden), a tertiary center for pediatric cardiology and thoracic surgery. Participants were fetuses referred for fetal cardiovascular magnetic resonance examination by a pediatric cardiologist after an inconclusive echocardiograph. Exposures: Fetal cardiovascular magnetic resonance examination requested by the patient's pediatric cardiologist. Main Outcomes and Measures: Any change in patient management because of diagnostic information gained from fetal cardiovascular magnetic resonance imaging. Results: A total of 31 fetuses underwent cardiovascular magnetic resonance examination at a median gestational age of 36 weeks (range, 31-39 weeks). Overall, fetal cardiovascular magnetic resonance imaging had clinical utility, affecting patient management and/or parental counseling in 26 cases (84%). For aortic arch anatomy including signs of coarctation (20 fetuses), fetal cardiovascular magnetic resonance imaging added diagnostic information in 16 cases (80%). For assessment of univentricular vs biventricular outcome in borderline left ventricle, unbalanced atrioventricular septal defect, and pulmonary atresia with intact ventricular septum (15 fetuses), fetal cardiovascular magnetic resonance imaging visualized intracardiac anatomy and ventricular function, allowing assessment of outcome in 13 cases (87%). In 4 fetuses with hypoplastic left heart syndrome, fetal cardiovascular magnetic resonance imaging helped delivery planning in 3 cases (75%). Finally, fetal cardiovascular magnetic resonance imaging provided valuable information for parental counseling in 21 cases (68%). Conclusions and Relevance: In this cohort study, fetal cardiovascular magnetic resonance imaging added clinically useful information to what was available from echocardiography. These findings suggest that fetal CMR has the potential to affect clinical decision-making in challenging cases of congenital heart defects with inconclusive data from echocardiography. Fetal cardiovascular magnetic resonance imaging showed an association with clinical decision-making, including mode of delivery and early postnatal care, as well as with parental counseling.


Assuntos
Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico , Imagem Cinética por Ressonância Magnética/estatística & dados numéricos , Diagnóstico Pré-Natal/métodos , Feminino , Seguimentos , Humanos , Gravidez , Reprodutibilidade dos Testes , Estudos Retrospectivos
20.
J Appl Physiol (1985) ; 130(4): 993-1000, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33539261

RESUMO

A hydraulic force generated by blood moving the atrioventricular plane is a novel mechanism of diastolic function. The direction and magnitude of the force is dependent on the geometrical relationship between the left atrium and ventricle and is measured as the short-axis atrioventricular area difference (AVAD). In short, the net hydraulic force acts from a larger area toward a smaller one. It is currently unknown how cardiac remodeling affects this mechanism. The aim of the study was therefore to investigate this diastolic mechanism in patients with pathological or physiological remodeling. Seventy subjects [n = 11 heart failure with preserved ejection fraction (HFpEF), n = 10 heart failure with reduced ejection fraction (HFrEF), n = 7 signs of isolated diastolic dysfunction, n = 10 hypertrophic cardiomyopathy, n = 10 cardiac amyloidosis, n = 18 triathletes, and n = 14 controls] were included. Subjects underwent cardiac MR, and short-axis images of the left atrium and ventricle were delineated. AVAD was calculated as ventricular area minus atrial area and used as an indicator of net hydraulic force. At the onset of diastole, AVAD in HFpEF was -9.2 cm2 (median) versus -4.4 cm2 in controls, P = 0.02. The net hydraulic force was directed toward the ventricle for both but was larger in HFpEF. HFrEF was the only group with a positive median value (11.6 cm2), and net hydraulic force was throughout diastole directed toward the atrium. The net hydraulic force may impede cardiac filling throughout diastole in HFpEF, worsening diastolic dysfunction. In contrast, it may work favorably in patients with dilated ventricles and aid ventricular filling.NEW & NOTEWORTHY It is a previously unrecognized physiological mechanism of the heart that diastolic filling occurs with the help of hydraulics. In patients with heart failure with preserved ejection fraction, atrial dilatation may cause the net hydraulic force to work against cardiac filling, thus further augmenting diastolic dysfunction. In contrast, it may work favorably in patients with dilated ventricles, as in heart failure with reduced ejection fraction.


Assuntos
Insuficiência Cardíaca , Diástole , Ventrículos do Coração/diagnóstico por imagem , Humanos , Volume Sistólico , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...